Yokogawa 414 Batch Controller Manuale Utente Pagina 22

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 59
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 21
20 Operation
3.3.2 Filtering
Frequency fluctuations caused by pulsating flow through a flowmeter, often makes
the Rate impossible to read with any precision. The Batch Controller has a digital
filter which will average out these fluctuations and enable the Rate to be read to
four digit accuracy. The ability to select a suitable filtering level means that highly
accurate and stable readings can be obtained without excessive lag.
The diagram below shows a pulsating signal input together with the effect of
filtering.
As a guideline to the degree of filtering to be used, the following table shows the
response to a step change in input. The value, A, is the filter constant which is
programmed during the Calibration routine. The times for the display value to
reach 90% and 99% of full swing are given in seconds, for different values of A.
Vedere la pagina 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 58 59

Commenti su questo manuale

Nessun commento